What Is a Plug Fan?:

Where Unhoused Centrifugal Fans Fit

By David Long

See next story

A plug fan is a centrifugal fan without its own spiral-shaped scroll housing. Instead of directing air through a built-in outlet, its wheel discharges into the surrounding plenum or process enclosure. This makes plug fans useful in equipment that already has a chamber designed to circulate or distribute process air.

The selection is not just about saving space. Airflow, pressure, inlet clearance, drive location and temperature must all work with the equipment layout. Those are the questions worth resolving before a plug fan is specified.

 

Where plug fans fit - and where they do not

Industrial ovens, dryers, evaporators and kilns already have chambers that can receive and distribute air. A plug fan can move air through that process path without a separate scroll housing or additional duct transition. Hartzell Series 12 plug fans are designed for these kinds of process-air circulation duties.

The same arrangement can help OEMs and retrofit projects keep equipment compact. Rather than adding a housed fan beside the enclosure, the wheel mounts within it. Mounting dimensions and service access still need to be planned from the beginning.

A housed centrifugal fan is often the more straightforward choice when air needs to leave through a defined outlet connected to ductwork. The better design follows the equipment's airflow path, not simply its available space.

 

The enclosure matters to performance

In a housed centrifugal fan, the manufacturer controls the wheel and scroll geometry. With a plug fan, the equipment enclosure also influences how air approaches and leaves the wheel. A nearby wall or restricted discharge path can affect installed performance.

Begin with the required airflow and resistance through filters, coils, product beds and other process passages. Then review the mounting position, inlet clearance, internal obstructions and return-air path. A published fan curve is only useful when the installation conditions behind the selection are understood.

These questions belong in the equipment-design review, before the enclosure dimensions are finalized.

 

Heat affects the drive arrangement

For ovens, kilns and other hot-process equipment, temperature is a selection factor, not just a material specification. Continuous temperature, startup or upset peaks and conditions at the motor location may all differ.

High-temperature service can affect the wheel, shaft, bearings, insulation and drive location. The maximum rating for one arrangement should never be assumed to apply to every version of the fan.

Hartzell's Series 12 literature is a useful example. It lists temperature constructions through 800°F, with special construction available for service up to 1,000°F subject to factory review. The same catalog limits Arrangement 4 to 200°F. The upper temperature rating is therefore a construction and arrangement decision, not a blanket rating for every Series 12 plug fan.

 

What to send with a plug-fan specification

Because the enclosure affects plug-fan performance, an application review should include:

  • Required airflow and the pressure or resistance the fan must overcome at the intended operating condition.
  • A drawing of the plenum or equipment, including mounting-panel dimensions, inlet clearance, internal obstructions and the intended airflow path.
  • Continuous and peak airstream temperatures, along with the temperature at the proposed motor and drive location.
  • Airstream composition: clean, dusty, moist, greasy, abrasive or chemically aggressive, plus any applicable process-safety requirements.
  • Operating schedule, available electrical power, speed-control requirements and how the maintenance team will access the wheel, bearings and drive.

An equipment sketch with these details gives Hartzell's application engineers a much better starting point than a model name alone.

 

Where Hartzell Series 12 fits

Hartzell Series 12 plug fans use a heavy-duty, single-thickness airfoil wheel. Published literature lists standard wheel diameters from 12 through 36 inches, Arrangements 4 and 9, and mounting-panel options for installation into equipment.

Matching that hardware to the application requires more than choosing a wheel size. The construction, drive location, temperature rating and surrounding airflow path all need to work together.

If you are integrating a plug fan into a new OEM design or replacing one in existing equipment, send us the duty point, temperatures and enclosure drawing. Hartzell's application engineers can review the arrangement with the equipment layout in mind.

1-800-336-3267 | info@hartzell.com

 

Frequently Asked Questions

Is a plug fan the same thing as a plenum fan?

The terms are sometimes used together, but they are not a guarantee of identical construction. A plug fan specifically describes an unhoused centrifugal wheel installed into equipment or a plenum. "Plenum fan" is also used for other air-handling configurations. Compare the wheel, mounting arrangement and performance data rather than relying on the name.

Does a plug fan need a housing?

It does not require its own scroll housing. It does require an appropriately designed plenum or equipment enclosure to contain and distribute the air, along with suitable supports and safety provisions.

Can plug fans handle high temperatures?

Yes, with construction selected for the actual duty. Hartzell Series 12 lists high-temperature options through 800°F, with special construction up to 1,000°F available by factory consultation. Arrangement-specific limits apply; Arrangement 4 is listed to 200°F.

What information is most important when specifying one?

Start with the operating airflow and resistance, then supply the enclosure layout, inlet clearances, continuous and peak temperatures, airstream conditions and intended motor and drive location.

When is a housed centrifugal fan the better choice?

When the application needs a defined outlet connected to ductwork and does not benefit from placing the wheel inside an existing enclosure. The whole airflow system, not simply available fan space, determines the better arrangement.

By David Long, Hartzell Air Movement, Vice President Sales

KEEP READING